Keep the flow unit with its reference conditions, and identify where pressure is required while air is being used. Add the demand pattern and air-quality requirements before comparing equipment capacities.
Keep the reference conditions beside the flow
Imagine adding an air-operated station to a production line. One sheet gives L/min, another gives L/min(ANR), and a compressor offer gives FAD. The numbers cannot be aligned by changing the unit label alone. First establish what volume each number represents.
SMC’s PFM7 manual gives a concrete example: its reference-display selection distinguishes flow converted to 20°C and 1 atm from flow converted to 0°C and 1 atm.[1] This is a definition for that device, not a rule that every catalogue uses the same conditions. Keep the source, temperature, absolute reference pressure and humidity basis, where applicable, with each value.
Atlas Copco describes free air delivery as delivered air expressed at inlet/free-air conditions and stresses consistent conditions when comparing capacities.[2] Ask for the offered compressor’s test/reference basis and the delivery pressure at which capacity is stated. A free-air equivalent volume is not the actual compressed volume passing through a pipe at operating pressure. Request a checked conversion when the bases differ; do not guess a common meaning for “normal”.
Identify the pressure location and operating state
A pressure at the compressor outlet does not describe every downstream point. Mark the line inlet, treatment equipment, distribution and consuming station on a simple layout. State the pressure needed at the relevant point during use, with the flow and operating condition that go with it.
Label pressure as gauge or absolute. Atlas Copco distinguishes their atmospheric and vacuum reference points, and describes differential pressure between two locations.[3] Keep a pressure drop across equipment separate from either an inlet or outlet pressure. If a sheet only says “0.6 MPa”, ask which reference and location it means before using it in a comparison.
- 1Capacity: retain the flow reference and the pressure for the offered equipment
- 2Distribution: identify treatment and pipework included in the enquiry
- 3Use point: pair required flow and pressure with the operating pattern
A sourcing information map, not a pipe sizing or pressure-system design. Numbers identify discussion areas, not ports or sensor positions; line sizes, pressure losses and treatment performance are not calculated.
Describe when air is needed and what the air must meet
Give normal demand, short peaks and their duration, and which stations may operate together. Distinguish air used per cycle from flow per minute and record the cycle rate when converting the demand. Atlas Copco’s sizing discussion separates continuous and intermittent consumption.[2] A daily average alone does not describe a brief simultaneous peak.
For an existing line, share available pressure/flow records with the measurement location, instrument basis and observation period. For a proposed station, identify assumptions and equipment-maker data. Ask the supplier what additional information is needed; the total of nameplate maxima and an unsupported diversity factor are not interchangeable demand estimates.
State the intended use and required particle, moisture and oil characteristics, including the applicable measurement basis or customer requirement. Ask where those requirements must be met and what evidence is included. A compressor capacity figure does not establish the outlet quality of an entire dryer/filter/distribution arrangement.
| Item | State in the enquiry | Confirm in the offer |
|---|---|---|
| Flow | State in the enquiryValue, unit, temperature, pressure and humidity/reference basis | Confirm in the offerComparable rated flow and any checked conversion |
| Pressure | State in the enquiryGauge/absolute, location and operating flow | Confirm in the offerCapacity at the stated pressure and any remaining downstream review |
| Demand pattern | State in the enquiryContinuous/cyclic use, peaks and simultaneous stations | Confirm in the offerAssumptions used for sizing and open data gaps |
| Treatment | State in the enquiryUse-point particle, moisture and oil requirements | Confirm in the offerApplicable conditions, evidence and treatment scope |
| Site and interfaces | State in the enquiryAmbient/inlet conditions, connection and installation limits | Confirm in the offerOperating envelope, utilities and exclusions |
| Verification | State in the enquiryMeasurement points, instruments and required records | Confirm in the offerWho confirms the agreed flow, pressure and air quality? |
Compare equipment on the same stated duty
Ask for the exact model and configuration, rated flow basis, pressure conditions, utilities and the work included. A compressor’s capacity, a filter’s processing flow and a station’s required flow have different roles; keep their definitions and applicable conditions visible when checking that they fit together.
Have the responsible supplier or system designer review distribution losses, transient demand and the treatment arrangement. This article does not select a receiver size, pipe size, pressure setting or air-quality class. Keep those design decisions and any additional tests with the offered configuration before accepting it.
Send HAM the equipment function, available data sheets, marked supply/use points, demand pattern, destination and questions still open. Agree which measurements or trials will confirm the order requirements. Keep unresolved conditions visible rather than treating an incomplete capacity comparison as an approved installation.
Questions to send your supplier
Open supplier questions
Equipment function, destination and proposed or existing installation: Required flow, unit and source of the number: Reference temperature, absolute pressure and humidity basis: Compressor FAD/test basis or other rated-flow definition: Required pressure: gauge/absolute, location and operating flow: Pressure-drop requirements and relevant inlet/outlet points: Continuous/cyclic demand, air per cycle, rate and short peaks: Stations operating together and sizing assumptions: Use-point particle, moisture and oil requirements and evidence: Ambient/inlet conditions, pipe/treatment scope and utilities: Measurement locations, instruments, trial and acceptance records: Exact configuration, exclusions, reviewer and unresolved questions:
Sources
- SMC — PFM7 flow switch manual PF-OMJ0005-H
Read printed page29 F4 reference-display definitions:20°C/1atm and0°C/1atm. Product-specific example; no universal ANR humidity, device settings or conversion factor adopted.
- Atlas Copco — Work, power and flow measurements
Read volumetric flow, FAD, reference conditions and demand pattern. Use the inlet-referenced definition; do not adopt inconsistent outlet-conditions wording elsewhere or a universal normal reference.
- Atlas Copco — Gauge and absolute pressure
Read gauge/absolute definitions and differential-pressure explanation. No fixed atmospheric-pressure conversion or installation pressure target adopted.